esphome-configs/kettle.yaml

173 lines
4.4 KiB
YAML
Raw Normal View History

2025-01-06 13:17:05 -05:00
substitutions:
name: proficook-pc-wks-1167g
friendly_name: ProfiCook PC-WKS 1167G
device_name: wks-1167g
esphome:
name: proficook-pc-wks-1167g
friendly_name: ProfiCook PC-WKS 1167G
esp32:
board: esp32-c3-devkitm-1
framework:
type: arduino # idf не працює, йде в bootloop
packages:
common: !include includes/common.yaml
wifi_sensors: !include includes/wifi.yaml
uart:
rx_pin: GPIO20
tx_pin: GPIO21
baud_rate: 9600
# Register the Tuya MCU connection
tuya:
id: tuya_tuya_id
climate:
- platform: tuya
name: "Kettle Climate"
target_temperature_datapoint: 102
current_temperature_datapoint: 105
switch_datapoint: 101
active_state:
datapoint: 106
visual:
min_temperature: 35
max_temperature: 100
temperature_step: 5
text_sensor:
- platform: template
name: Kettle State
icon: mdi:kettle
id: text_state
- platform: template
name: Kettle Error
icon: mdi:alert-circle-outline
id: text_error
select:
- platform: template
name: "Kettle mode"
id: kettle_control
options:
- 45°
- 60°
- 85°
- 100°
- 100° and off
- Custom
- "Off"
optimistic: true
set_action:
- lambda: |-
if (strcmp(x.c_str(), "45°") == 0) {
id(tuya_tuya_id).set_enum_datapoint_value(101, 0);
} else if (strcmp(x.c_str(), "60°") == 0) {
id(tuya_tuya_id).set_enum_datapoint_value(101, 1);
} else if (strcmp(x.c_str(), "85°") == 0) {
id(tuya_tuya_id).set_enum_datapoint_value(101, 2);
} else if (strcmp(x.c_str(), "100°") == 0) {
id(tuya_tuya_id).set_enum_datapoint_value(101, 3);
} else if (strcmp(x.c_str(), "100° and off") == 0) {
id(tuya_tuya_id).set_enum_datapoint_value(101, 4);
} else if (strcmp(x.c_str(), "Custom") == 0) {
id(tuya_tuya_id).set_enum_datapoint_value(101, 5);
} else {
id(tuya_tuya_id).set_enum_datapoint_value(101, 6);
}
number:
- platform: "tuya"
id: custom_temp
name: "Kettle Custom Temperature"
number_datapoint: 102
icon: mdi:oil-temperature
min_value: 35
max_value: 100
step: 1
sensor:
update_interval: 60s
- platform: template
name: Kettle Temperature
id: kettle_temp
unit_of_measurement: "°C"
accuracy_decimals: 0
- platform: tuya
id: tuya_105
sensor_datapoint: 105
on_value:
then:
- if:
condition:
lambda: |-
return static_cast<int>(id(tuya_106).state) == 1;
then:
- sensor.template.publish:
id: kettle_temp
state: !lambda |-
return 0;
else:
- sensor.template.publish:
id: kettle_temp
state: !lambda |-
return id(tuya_105).state;
- platform: tuya
id: kettle_remaining
name: Kettle Remaining Time
icon: mdi:clock-time-five-outline
sensor_datapoint: 107
unit_of_measurement: "min"
accuracy_decimals: 0
- platform: tuya
id: tuya_101
sensor_datapoint: 101
on_value:
then:
- select.set_index:
id: kettle_control
index: !lambda |-
return id(tuya_101).state;
- platform: tuya
id: tuya_106
sensor_datapoint: 106
on_value:
then:
- text_sensor.template.publish:
id: text_state
state: !lambda |-
switch(static_cast<int>(id(tuya_106).state)) {
case 1: return {"Lifted"};
case 2: return {"Standby"};
case 3: return {"Heating"};
case 4: return {"Cooling"};
case 5: return {"Maintaining Temp"};
default: return {""};
}
- platform: tuya
id: tuya_104
sensor_datapoint: 104
on_value:
then:
- if:
condition:
lambda: |-
return id(kettle_temp).raw_state == 0;
else:
- text_sensor.template.publish:
id: text_error
state: !lambda |-
switch(static_cast<int>(id(tuya_104).state)) {
case 0: return {"OK"};
case 1: return {"Empty"};
case 4: return {"Overheated"};
default: return {"other error"};
}